19 май 2011

FTXN-K / RXN-K





FTXN50K, RXN50K ,FTXN50KV1B, RXN50KEV1B

FTXN60K, RXN60K ,FTXN60KV1B, RXN60KEV1B




PRODUCTNAMEFTXN50KV1B / RXN50KEV1B
Cooling capacityMin.kW1.7
Min.Btu/h5.800
Min.kcal/h1.460
Nom.kW5.0 (3)
Nom.Btu/h17.100 (3)
Nom.kcal/h4.300 (3)
Max.kW5.7
Max.Btu/h19.400
Max.kcal/h4.900
Heating capacityMin.kW1.7
Min.Btu/h5.800
Min.kcal/h1.460
Nom.kW5.5 (4)
Nom.Btu/h18.800 (4)
Nom.kcal/h2.320 (4)
Max.kW6.8
Max.Btu/h23.200
Max.kcal/h5.850
Power inputCoolingMin.kW0.322
Nom.kW1.560
Max.kW2.005
HeatingMin.kW0.319
Nom.kW1.570
Max.kW2.285
EER 3.21
COP 3.50
Energy labelCoolingA
HeatingB
Annual energy consumptionkWh780
Piping connectionsLiquidODmm6.35
GasODmm12.7
DrainTypeHole
ODmm18.0
Heat insulationBoth liquid and gas pipes
Notes Energy label: scale from A (most efficient) to G (less efficient)
Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions)
Cooling: indoor temp. 27CDB. 19CWB; outdoor temp. 35CDB. 24CWB; equivalent piping length: 5m
Heating: indoor temp. 20CDB; outdoor temp. 7CDB. 6CWB; equivalent refrigerant piping: 5m






PRODUCTNAMEFTXN50KV1B
Power inputCoolingNom.kW0.034
HeatingNom.kW0.036
CasingColourWhite
DimensionsUnitHeightmm290
Widthmm1.050
Depthmm238
Packed unitHeightmm337
Widthmm1.147
Depthmm366
WeightUnitkg12
Packed unitkg17
Heat exchangerLengthmm863
RowsQuantity2
Fin pitchmm1.4
StagesQuantity16
Tube type7 Hi-XA
FinTypeML fin (Multi louver)
FanTypeCross flow fan
Air flow rateCoolingHighm/min14.7
Highcfm519
Nom.m/min12.4
Nom.cfm438
Lowm/min10.3
Lowcfm364
Silent operationm/min9.5
Silent operationcfm335
HeatingHighm/min16.1
Highcfm568
Nom.m/min13.9
Nom.cfm491
Lowm/min11.5
Lowcfm406
Silent operationm/min10.2
Silent operationcfm360
Fan motorModelARW30R8P43DA
SpeedSteps5
silent.
auto
CoolingHighrpm1.240
Mediumrpm1.090
Lowrpm930
Silent operationrpm860
HeatingHighrpm1.270
Mediumrpm1.110
Lowrpm960
Silent operationrpm870
OutputHighW43
Sound power levelCoolingNom.dBA59
HeatingNom.dBA58
Sound pressure levelCoolingHighdBA43
Nom.dBA39
LowdBA34
Silent operationdBA31
HeatingHighdBA42
Nom.dBA38
LowdBA33
Silent operationdBA30
Piping connectionsLiquidODmm6.35
GasODmm12.7
DrainI.D. 14.0/O.D. 18.0
Heat insulationBoth liquid and gas pipes
Air filter Removable / washable / mildew proof
Air direction control Right. Left. Horizontal. Downward
Temperature control Microcomputer control
Standard AccessoriesItemTitanium apatite photocatalytic air purification filter
Quantity2
ItemOperation manual
Quantity1
ItemInstallation manual
Quantity1
ItemWireless remote control
Quantity1
ItemBatteries
Quantity2
ItemRemote control holder
Quantity1
ItemIndoor unit fixing screws
Quantity2
ItemMounting plate
Quantity1
Power supplyPhase1
FrequencyHz50
VoltageV220-240
CurrentNominal running current (RLA) - 50HzCoolingA0.16 (1)
0.15 (2)
0.1 (3)
HeatingA0.17 (1)
0.16 (2)
0.16 (3)
Notes 220V
230V
240V

PRODUCTNAMERXN50KEV1B
CasingColourIvory white
DimensionsUnitHeightmm595
Widthmm795
Depthmm300
Packed unitHeightmm654
Widthmm942
Depthmm400
WeightUnitkg42
Packed unitkg45
Heat exchangerLengthmm870
RowsQuantity2
Fin pitchmm1.4
StagesQuantity26
Tube type8 Hi-XA
FinTypeWaffle louvered fin
FanTypePropeller fan
Air flow rateCoolingHighm/min42.6
Highcfm1.504
Super lowm/min37.6
Super lowcfm1.328
HeatingHighm/min38.3
Highcfm1.352
Super lowm/min33.8
Super lowcfm1.193
Fan motorModelKFD-280-60-8C
OutputW60
SpeedCoolingHighrpm900
Super lowrpm800
HeatingHighrpm900
Super lowrpm800
CompressorModel2YC36BXD
TypeHermetically sealed swing compressor
OutputW1.100
Operation rangeCoolingAmbientMin.CDB10
Max.CDB46
HeatingAmbientMin.CWB-15
Max.CWB18
Sound power levelCoolingHighdBA63
Sound pressure levelCoolingHighdBA49
Silent operationdBA46
HeatingHighdBA51
Silent operationdBA48
RefrigerantTypeR-410A
Chargekg1.45
Refrigerant oilTypeFVC50K
Charged volumel0.65
Piping connectionsLiquidODmm6.35
GasODmm12.7
DrainTypeHole
IDmm18.0
Piping lengthOU - IUMax.m30
Level differenceIU - OUMax.m20
Heat insulationBoth liquid and gas pipes
Standard AccessoriesItemInstallation manual
Quantity1
ItemDrain plug
Quantity1
Power supplyPhase1
FrequencyHz50
VoltageV220-240
CurrentNominal running current (RLA)CoolingA7.14 (1)
6.75 (2)
6.55 (3)
HeatingA7.13 (1)
6.84 (2)
6.54 (3)
Starting currentCoolingA7.3
HeatingA7.3
Wiring connectionsFor power supplyQuantity3
For connection with indoorQuantity4
RemarkEarth wire included
Notes 220V
230V
240V



07 февруари 2011

cooling at low outdoor temperature

Facility Setting Switch (RKS60F3V1B, RKS50G2V1B, RKS60F2V1B only)
cooling at low outdoor temperature



This function is limited only for facilities (the target of air conditioning is equipment (such as computer)). Never use it in
a residence or office (the space where there is a human).
1) You can expand the operation range to –15°C by turning on switch B (SW4) on the PCB. If the outdoor temperature falls
to –20°C or lower, the operation will stop. If the outdoor temperature rises, the operation will start again.
CAUTION
• If the outdoor unit is installed where the heat exchanger of the unit is exposed to direct wind, provide a windbreak wall.
• Intermittent noises may be produced by the indoor unit due to the outdoor fan turning on and off when using facility settings.
• Do not place humidifiers or other items which might raise the humidity in rooms where facility settings are being used.
A humidifier might cause dew jumping from the indoor unit outlet vent.
• Use the indoor unit at the highest level of airflow rate.

06 февруари 2011

Фирми Климатици втора употреба

Климатици втора употреба
Варна
http://japanclima.com/
http://www.varnaklima.com/
http://www.termo-klima.com/bul/marka.php?maker_id=62
http://regataklima.netne.net/index.php?p=2_23

Пловдив
НТТ - 3 ООД - Климатични инсталации  http://informator.bg/cgi-bin/index.pl?_state=Info&ID=3564
http://valdesbg.com/klimatici/vtora-upotreba.html

05 февруари 2011

DAIKIN FTXL-G Defrost

Inverter Pair G-Series

Heat Pump
Indoor Units
FTXL20G2V1B
FTXL25G2V1B
FTXL35G2V1B
Outdoor Units
RXL20G2V1B
RXL25G2V1B
RXL35G2V1B

Outline Defrosting is carried out by the cooling cycle (reverse cycle). The defrosting time or outdoor
heat exchanger temperature must be more than its fixed value when finishing.
Detail Conditions for Starting Defrost
The starting conditions must be made with the outdoor air temperature and heat exchanger
temperature. Under the conditions that the system is in heating operation, 6 minutes after the
compressor is started and more than 28 minutes (20 class), 30 minutes (25 class), or 44
minutes (35 class) of accumulated time pass since the start of the operation or ending the
defrosting.
Conditions for Canceling Defrost
The judgment must be made with heat exchanger temperature.
(20 class : 4°C-22°C, 25 class : 4°C-15°C, 35 class : 4°C-12°C)

DAIKIN FTXS Defrost

FTXS20G2V1B
FTXS25G2V1B
FTXS35G2V1B
FTXS42G2V1B
FTXS50G2V1B

Detail Conditions for Starting Defrost

The starting conditions must be made with the outdoor air temperature and heat exchanger
temperature. Under the conditions that the system is in heating operation, 6 minutes after the
compressor is started and more than 28 minutes (20/25/35 class), 30 minutes (42 class), or 44
minutes (50 class) of accumulated time pass since the start of the operation or ending the
defrosting.

Conditions for Canceling Defrost

The judgment must be made with heat exchanger temperature.
(20/25/35 class : 4°C-22°C, 42 class : 4°C-15°C, 50 class : 4°C-12°C)

27 януари 2011

Service manual DAIKIN Wall Mounted Type G-Series GV series

Service manual DAIKIN Wall Mounted Type G-Series GV series
модели
FTX20GV
FTX25GV
FTX35GV
 
Cooling Only

Indoor Units
FTK20GV1B
FTK25GV1B
FTK35GV1B
Outdoor Units
RK20GV1B
RK25GV1B
RK35GV1B

Heat Pump
Indoor Units
FTX20GV1B ATX20GV1B
FTX25GV1B ATX25GV1B
FTX35GV1B ATX35GV1B
Outdoor Units
RX20GV1B ARX20GV1B
RX25GV1B ARX25GV1B
RX35GV1B ARX35GV1B